Customization: | Available |
---|---|
After-sales Service: | Vaporized Decontamination Bath |
Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Vapor Degreaser Cleaning Solvent Degreasing Tank Vapour Cleaner
01: Application
Vapor Degreaser Cleaning Solvent Degreasing Tank Vapour Cleaner acquires another tech name solvent condensation cleaning, that executes powerful, efficient, sustainable and reliable degreasing process in a matter of seconds removes contaminants like machining oil, cutting fluids, waxes, solder flux, polishing, buffing agent, and more via solvent cleaning, many industries from electronics firms to aerospace companies to metal fabricators user Vapor Degreaser Cleaning Solvent Degreasing Tank Vapour Cleaner to precision clean metal and machined parts, because of the comprehensive and fast cleaning capability combined with no need for rinsing and drying, that utilizes non-flammable, non-hazardous, no-toxic, low boiling temperature and low surface tension azeotropic solvent, which can be recycled and reused for reduced operating costs
Vapor Degreaser Cleaning Solvent Degreasing Tank Vapour Cleaner pioneers reliability in industrial cleaning process, such as electronic: printed circuit board and other electronic manufactures use vapor degreasing for the removal of flux and polar contaminants from printed circuit boards and the cleaning electronic assemblies; aerospace: vapor degreasing is widely used by aerospace manufacturing firms for precision and general vapor degreasing for dye removal in non-destructive testing application, pre-plating and pre-coating cleaning and post-plating/coating and masking wax and adhesive removal; optics: cleaning of fingerprints, buffing and potting compounds and waxes; general metal fabrication and finishing: metal fabricators user vapor degreasing for the removal of typical fabrication on contaminants including greases, lubricants and cutting fluids
02: Tech Data
Keyword |
Vapor Degreaser Cleaning Solvent Degreasing Tank Vapour Cleaner |
Model |
KLE-1096R |
Electric Connection |
380v,60hz, Three Phase, Five Wires |
Max process Capacity |
1600*1000*3500mm |
Heating Power |
15000W |
Refrigerator Power |
5Hp |
Distilled Spraying Wand Power |
1000w |
Exhausting Pump Power |
500W |
Solvent Capacity |
320 Liters |
Low Level Control Depth |
100~200mm |
Max Loading Weight |
800kgs |
Distillation Rate |
120L/H |
Temperature Control |
Within 100 Celsius |
Vapor Zone |
1600*1000*980mm |
Maximum Loading Height |
3500mm |
Heating-up Time |
5~10 Minutes |
Material |
Stainless Steel 316 of thickness: 3mm |
Overall Dimension |
1863*1264*4655mm |
Packing Size |
4.75*1.95*1.58m=14.63 CBM&1.5*1.0*1.5m=2.25CBM |
Weight |
1680kgs |
03: Salient Characters
Vapor condensation cleaning and drying in one chamber
Refrigerated primary condenser and Chilly water secondary cooling blanket
Extended free-board ratio to minimize diffusion losses
Manually hermetic sealing tank cover to control overhead air turbulence losses
Water separator continuous remove condensed atmospheric moisture from the system
The level and temperature of vapor automatic monitoring to alert operator in timely maintenance, service
All Chamber, canister and coils made of stainless steel 316, wall thickness 3mm.
Copper/brass plumbing's and, stainless cooling coils
High vapor sensor and high solvent temperature sensor to cut off heater and halt the refrigerator.
Low solvent level control, disables heaters and advises operator if solvent level is low
Hand-held distillate spray wand to execute flexible solvent jet blasting
Designed to use all types of non-flammables degreasing solvent.
Pickled, passivation and electron polished to extend operation life.
Heated tanks have direct contact tube heaters for energy efficiency and longevity.
On-board distillation ensures clean solvent continuously.
Free-board dwell ensures completely dry component at end of process.
Compact footprint designed for clean room application
Easy to use-minimal operator training required
Built-in top exhausting fan to control the solvent vapor dissipation
Hanging type refrigerator decide accept flexible installation
Supportive frame at the beneath of tank can bear maximum 800kgs loading
four sectional square compose a completed vapor chamber with reinforced welding seam
Standing-along power cabinet is convenient moveable during integrated installation.
Vapor Degreaser Cleaning Solvent Degreasing Tank Vapour Cleaner should take advanced consideration precede applicable recommendation or solution, such as subsequent elements.
Chamber size: sizing of the vapor degreaser is fairly straight-forward as it is dictated by the weight and size of the part basket, this is usually a combination of the amount of parts tht need to be cleaned/production rate, the weight and size of the parts, how complex the parts are and type of contaminant that is being cleaned; production through-put: start by considering how many parts need to process an hour, keep in mind the larger the tank of vapor degreaser, the more expense; size and complexity of parts: the size will dictate the number of parts per basket or increasing the tank size for processing, and complexity might mean immersion or ultrasonic is needed; weight of part: heavy parts require more heat input to ensure the vapor zone does not collapse when the parts are immersed in the zone; contaminant type: light machining oils require less processing, and possibly just vapor cleaning versus needing immersion or ultrasonic to clean the parts; electrical needs: ultrasonic and heat requirements will dictate electrical needs; floor space: even though the Vapor Degreaser Cleaning Solvent Degreasing Tank Vapour Cleaner is pretty compact system, the refrigeration systems require air circulation//good ventilation; automation: automated basket handing system and hoist systems are available to provide consistent basket processing and thus consistent cleaning; ceiling height: large systems can be tall, so ceiling height does become a consideration; door frame restriction: moving the degreaser from shipping dock to final location might mean doors; ventilation: overhead ventilation is not recommended as it reduces the efficiency of refrigeration systems on the Vapor Degreaser Cleaning Solvent Degreasing Tank Vapour Cleaner by pulling the solvent past the refrigeration coils, ventilation is usually at the floor if at all; chiller capacity: on the larger units, the chiller for the primary refrigeration unit is usually placed outside or in a separate location, the secondary refrigeration system is usually on the platform with the vapor degreaser itself
Cleaning is critical to achieve a high quality aerospace parts surface finish, by using a Vapor Degreaser Cleaning Solvent Degreasing Tank Vapour Cleaner and modern, advanced cleaning solvent fluids, the cleaning process is simple, consistent and sustainable producing perfect prepped parts, Vapor Degreaser Cleaning Solvent Degreasing Tank Vapour Cleaner is cost-effective in ensuring parts are clean, and it addresses worker safety, regulatory requirements and environmental concerns, whatever you solely have perception or practical proven prototype, by which to initiate your collaborative fabrication, keepleader, we are definitely a reliable partner to trust in implementing your construction, now, we are ready for your tech consultation, don't hesitate to contact us when you are engaging in industrial cleaning process